CNC / DNC Settings for Fanuc OM

Parameter Value Comments  
 
0002 00000001  
0552 9 Baud rate - see table below for valid options.
  6 = 300
7 = 600
8 = 1200
9 = 2400 * (recommended)
10 = 4800
11 = 9600
 
TV On/Off 0 0 = TV Check OFF (1= TV Check ON - Never enable TV Check)
ISO 1 1 = ISO (0=EIA Never use EIA)
I/O 0  
     
Drip Feed ?

To drip feed enable para G127.5
Select Auto (DNC) mode on the control - Press Cycle Start.
Then go to the computer, prepare the program and click 'Send'. When data begins to flow the machine will start moving.

Looking for DNC Software ??
We recommend easyDnc 4.0 for Windows 95, 98, 2000, XP and Windows Vista

Cable type 1 is common but Cable 2 is recommended because it supports both software and hardware flow control and is compatible with a wider range of CNC types/modes.The above diagrams assume your cable has 9pin connector - If your computer has the old 25pin com port then see www.dnccable.com for more info.