CNC / DNC Settings for Fanuc 16 (16M 16T)

Parameter Value Comments  
 
0000 00000010  
0020 0  
0100 0  
0101 10000001  
0102 0  
0103 9 Baud rate - see table below for valid options.
  6 = 300
7 = 600
8 = 1200
9 = 2400 * (recommended)
10 = 4800
11 = 9600
 
TV Check 0 0 = TV Check OFF (1= TV Check ON - Never enable TV Check)
Punch Code 1 1 = ISO (0=EIA Never use EIA)
I/O Channel 0  
Tape Format 0  
     
Drip Feed ?

Select TAPE mode on the control - Press Cycle Start.
Then go to the computer, prepare the program and click 'Send'. When data begins to flow the machine will start moving.

Looking for Dnc Software ?
We recommend easyDnc 4.0 for Windows 95, 98, 2000, XP and Windows Vista

Cable type 1 is common but Cable 2 is recommended because it supports both software and hardware flow control and is compatible with a wider range of CNC types/modes.


The above diagrams assume your cable has 9pin connector - If your computer has the old 25pin com port then see www.dnccable.com for more info.